Page 4-6 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
Table 4-1. Maintenance Intervals, Cont.
Item Description/Procedure
Manual
Section No.
Interval
G1000 Lightning Protection
G1000 System
Replace all lightning protection 3.2
Amp slow-blow fuses.
4.12 24 months
GIA / AHRS Resistors
Replace all 3 resistors located on the front of
the remote avionics enclosure. Refer to
G1000/DA40 Installation Drawing,
005-00304-00.
For WAAS aircraft:
In addition to the above 3 resistors, replace
all 7 resistors located on the resistor bracket
installed on the side of the remote avionics
enclosure. See the Resistor Install Drawing,
005-00400-12.
N/A
Replace After
Suspected / Actual
Lightning Event
TVS Unit
Replacement
(Qty 7)
Replace all five voltage suppressor units.
Refer to G1000/DA40 Installation Drawing,
005-00304-00:
9 Battery, Alternator, GMA 1347, and
Standby Attitude Indicator Voltage
Suppressors are located behind
instrument panel near the circuit
breakers.
9 GIA1, GIA2, and AHRS Voltage
Suppressors are located at the remote
avionics enclosure.
N/A
Replace After
Suspected / Actual
Lightning Event
Visual Inspection Complete Visual Inspection. 4.4
After
Suspected / Actual
Lightning Event
Electrical Bonding
Test
Perform an electrical bonding resistance
check of all G1000 equipment.
4.5
1000 Hours and
After
Suspected / Actual
Lightning Event